Operation 
6
309286K
Operation
Pressure Relief Procedure
Follow this procedure when you stop spraying and 
before cleaning, checking, servicing or transporting 
equipment.
1.
Engage trigger lock.
2.
Turn pressure washer OFF.
3.
Remove ignition cap from spark plug.
4.
Turn off water supply and disconnect pressure 
washer from water.
5.
Unlock trigger lock. Trigger gun to relieve pressure. 
Engage trigger lock.
TIA
ti5424a
ON
OFF
If you suspect the spray tip or hose is clogged or 
that pressure has not been fully relieved after fol-
lowing the pressure relief procedure, VERY 
SLOWLY loosen tip guard retaining nut or hose end 
coupling to relieve pressure gradually, then loosen 
completely. Clear hose or tip obstruction.
ti5425a
ti5427a