CLEANING THE GENERATOR
1.  Use a damp cloth to wipe exterior surfaces clean.
2.  A soft, bristle brush may be used to loosen caked on dirt, oil, etc.
3.  A vacuum cleaner may be used to pick up loose dirt and debris.
4.  Low  pressure  air  (not  to  exceed  25  psi)  may  be  used  to 
blow  away  dirt.  Inspect  cooling  air  slots  and  openings  on  the 
generator. These openings must be kept clean and unobstructed.
5.  Inspect  the  vent  hoses  on  the  left  side  of  the  generator.  Make 
sure the hoses protrude through the slots below the door and that 
the ends are open and free of debris.
ENGINE MAINTENANCE
‹
 Only work on a generator that has cooled 
completely.
Inspect  the  oil  level  and  air  filter  condition  each  time  you  are  going 
to use the generator. To check the air filter and oil level the left side 
service  cover  must  be  removed;  use  a  screwdriver  to  loosen  the 
screw securing the cover and remove.
The air filter is located behind a cover for the air box (Figure 10). Push 
the tab on the bottom of the air box upwards to release the cover. To 
service the air cleaner:
1.  Remove  the  air  cleaner.  Tap  the  element  to  shake  loose  any 
large particles.
2.  Wash the element in soapy water. Squeeze the filter dry in clean 
cloth (DO NOT TWIST).
3.  Soak the filter element in clean engine oil. Squeeze the excess 
oil from the filter, leaving a light coating.
4.  Clean air cleaner housing and cover before re-installing the filter 
element.
Figure 10 - Air Filter
AIR
FILTER
FILTER
HOUSING
COVER
LEFT SIDE
SERVICE COVER
SCREW
LEFT SIDE
SERVICE
COVER
CHANGING THE ENGINE OIL
‹
 Hot oil may cause burns. Allow engine to cool 
entirely before draining oil. Avoid prolonged 
or repeated skin exposure with used oil. 
Thoroughly wash exposed areas with soap.
Change the engine oil after the first five (5) hours of operation. Change 
the engine oil every 100 hours thereafter. To change the engine oil:
1.  Run the generator briefly to warm the engine oil; this also loosens 
any engine deposits and makes the used oil flow easier.
‹
 Change the oil only when the fuel tank is low 
or nearly empty. Tipping the generator with a 
full fuel tank may cause fuel leakage.
2.  Place  the  generator  over  a  drain  pan  and  remove  the  drain 
plug. Tip the generator on its side to drain the used oil from the 
crankcase.
NOTE:
To make draining the oil easier, a 6” length of vinyl (PVC) hose 
with an inside diameter of 1.25” (32mm) any be placed over the 
drain lip.
3.  Tip  the  generator  upright  once  the  oil  has  finished  draining. 
Replace the engine oil with the proper grade called out in Section 
“ADDING ENGINE OIL”, then replace the drain plug.
CHANGING THE FUEL FILTER
Locate the fuel filter, just below the engine intake housing (Figure 11). 
Make sure the Fuel Shutoff is in the “OFF” (O) position.
1.  Remove the pinch clamps securing the fuel filter. Pull the hoses 
free.
‹
 Wipe up any fuel spills immediately! Do not 
smoke or replace the fuel filter near sparks or 
open flame!
2.  Replace the used filter with a new one. Push the fuel hoses onto 
the barbed filter fittings until they are seated completely.
3.  Replace the clamps, making sure they are seated on the fittings.
Maintenance