 Hot oil may cause burns. Allow engine to cool before 
draining oil. Avoid prolonged or repeated skin exposure 
with used oil. Thoroughly wash exposed areas with soap.
Use the following instructions to change the oil:
Clean area around oil drain cap.
• 
Remove oil drain cap from the drain hose and dipstick to drain 
• 
oil completely into a suitable container.
When oil has completely drained, install oil drain cap and tighten 
• 
securely.
Place a suitable container beneath the oil filter and turn 
• 
filter counterclockwise to remove. Discard according to local 
regulations.
Coat gasket of new filter with clean engine oil. Turn filter 
• 
clockwise until gasket contacts lightly with filter adapter. Then 
tighten an additional 3/4 turn.
Fill engine with recommended oil and replace the dipstick. (See 
• 
“Before Starting the Generator” for oil recommendations).
Wipe up any spilled oil.
• 
Dispose of used oil at a proper collection center.
• 
3.3.6  REPLACING THE SPARK PLUG(S)
Use NGK BPR6HS spark plugs or equivalent. Replace the plugs 
once each year. This will help the engine start easier and run 
better.
1.  Stop the engine and pull the spark plug wires off of the spark 
plugs.
2.  Clean the area around the spark plugs and remove them from 
the cylinder heads.
3.  Set the spark plug gaps to .76 mm (0.030 in.). Install the 
correctly gapped spark plug into each cylinder head (Figure 
12).
4.  Push the boots firmly on the spark plugs.
Figure 12 – Spark Plug Gap
3.4  SERVICE AIR CLEANER
The engine will not run properly and may be damaged if using a 
dirty air cleaner. Clean or replace the air cleaner paper filter every 
200 hours or once a year . Clean or replace more often if operating 
under dusty conditions. To clean or replace paper air filter:
Remove air cleaner cover and remove paper filter (Figure 13).
• 
Clean paper filter by tapping it gently on a solid surface. If the 
• 
filter is too dirty, replace it with a new one. Dispose of the old 
filter properly.
Clean air cleaner cover. Next insert new paper filter into the base 
• 
of the air cleaner. Re-install air cleaner cover.
NOTE:
To order a new air filter, please contact the nearest authorized 
service center at 1-888-GENERAC.
Figure 13 – Air Filter
3.5  CLEAN SPARK ARRESTOR SCREEN
The engine exhaust muffler has a spark arrestor screen. Inspect 
and clean the screen at least once each year (Figure 14). If unit is 
used regularly, inspect and clean more often.
 If using the generator on any forest-covered, 
brush-covered or grass-covered unimproved 
land, it must equipped with a spark arrestor. 
The spark arrestor must be maintained in good 
condition by the owner/operator.