Roland MC-909 사용자 설명서

다운로드
페이지 180
 
89
Effects
 
Effects
 
If you change the “Output Assign” setting, the routing connections 
in the screen will also change.
 
Parameters 4–11 in the above table are linked with the identically 
named parameters in the setting screens of each effect.
 
Compressor
 
The compressor is an effect that limits the level of loud sounds and 
boosts the level of soft sounds, making the overall level more 
consistent.
 
fig.4-03
 
7.
 
 
MFX1 Reverb 
Send Level
0–127
Depth of reverb applied to the 
sound processed through 
multi-effects 1
Set this to 0 if you don’t 
want to apply reverb.
 
8.
 
 
MFX1 Output 
Assign
DRY, MFX2
Output destination of the 
sound processed through 
multi-effects 1
 
DRY:
 
 MIX OUTPUT jacks
 
MFX2:
 
 Multi-effects 2 
(multi-effects 1 and 2 will be 
connected in series)
 
9.
 
 
(MFX Type)
See “Multi-Ef-
fects List” (p. 
92)
The effect used by multi-ef-
fects 2
* For details on each effect, 
refer to “Multi-Effects List” 
(p. 92).
 
10.
 
 
MFX2 Reverb 
Send Level
0–127
Depth of reverb applied to the 
sound processed through 
multi-effects 2
Set this to 0 if you don’t 
want to apply reverb.
 
11.
 
 
(Reverb Type)
See “Reverb” 
(p. 90)
The type of reverb
* For details on reverb, refer 
 
Parameter
Range
Explanation
Parameter
Range
Explanation
 
Comp Reverb 
Send Level
0–127
Depth of reverb applied to the 
sound processed through the 
compressor
Set this to 0 if you don’t 
want to apply reverb.
Comp Output 
Assign
DRY, MFX1, 
MFX2
Output destination of the 
sound processed through the 
compressor
 
DRY:
 
 MIX OUTPUT jacks
 
MFX1 (2):
 
 Multi-effects 1 
(or 2)
Attack Time
0.05–50 ms
Time from when the volume 
goes up the threshold level 
until the compressor effect ap-
plies
Release Time
0.05–2000 ms
Time from when the volume 
falls below the threshold level 
until the compressor effect no 
longer applies
Threshold
0–127
Volume level at which com-
pression begins
Ratio
1:1–inf:1
Compression ratio (inf: infini-
ty)
Output Gain
0– +24 dB
Level of the output sound
Low Freq
200, 400 Hz
Reference frequency of the 
low range
Low Gain
-15– +15
Amount of low-range boost/
cut
High Freq
2k, 4k, 8kHz
Reference frequency of the 
high range
High Gain
-15– +15
Amount of high-range boost/
cut
Level
0–127
Output volume of the com-
pressor
MC-909_Ref_e.book 89 ページ 2005年3月1日 火曜日 午後3時29分