TC12 Installation, Commissioning & Maintenance Handbook 
•  Equipment is CE marked and self-certified to RTE Directive 99/5/CE R&TTE. 
BABT approval no longer appropriate. References to BABT removed 
throughout document. 
•  Clarification to battery change procedures, sections 3.4.5 and 6.5.4. 
•  Instation Power Supply replacement procedure added to section 2.4.10. 
•  General updates to formatting and spelling. 
•  Preface removed, since the information it gave is available from the table of 
contents. 
 
Issue 8 - Significant changes for this issue: 
•  Changes to reflect introduction of RS232 OTU communications interface. 
•  Instation software installation procedure revised 
 
Issue 9 - Significant changes for this issue (July 2004): 
•  Changed OTU PCB part number to /100 from /001 and added Integral OTU kit 
part number to section 6.5.5. 
•  Added TC12 inputs specification to section 3.2.3.5. 
•  Edited section 3.4.1 – Status LEDs. 
•  Added codes 83-91 to Function Group 1 of Display Fault Data section 
3.3.3.28. 
 
1.6 
TC12 SYSTEM OVERVIEW 
TC12 is a telecommunications system designed for Urban Traffic Control (UTC). It 
consists of a number of Outstation Transmission Units (OTUs) positioned in the 
traffic controllers or detector cabinets. These communicate with a central office 
containing a number of Instation Transmission Units (ITUs). Communication 
between the two is by means of private wire telephone lines, which can be 
operated at different baud rates and signal levels. 
 
The ITU sends a Control message to the OTU that will cause the OTU to form the 
appropriate Reply message, which it will send back. These messages are of 
configurable size depending on the amount of data transfer needed. 
 
The ITU connects to a Traffic Control Computer (TCC) system consisting of one or 
more UTC TCC computers and one or more PCs communicating with each other 
via an Ethernet link. This system drives the ITU modems, which communicate with 
the OTU via the telephone lines. 
 
The ITU also drives the System Fault Indication Panel (SIP) which indicates, by 
means of LEDs and an audible alarm, failures in the TCC. The SIP is housed in 
the ITU cabinet but there is also the option of driving a remote SIP. The ITU can 
also be used to drive a TC8 Instation. 
 
There is also facility for an Instation Test Set which can be used to measure signal 
levels and monitor communications (both data and errors) on the telephone lines. 
It can also be used to take the place of either Instation or Outstation for testing. 
 
666/HE/43100/000  
Page 4 
Issue 9