TC12 Installation, Commissioning & Maintenance Handbook 
4.3.2.3  Connection to OTU PCB 
There are two sockets on the front of the OTU PCB. The sockets are labelled on 
the silk screen. The top socket is reply and the bottom socket is control. 
 
4.3.3  Front Panel Switches 
4.3.3.1 Mains Switch 
Mains switch and PC switch 
 
Switching the Test Set off, using the rocker switch on the front panel, does NOT 
guarantee isolation from the mains. 
 
4.3.3.2  Modem Mode Switch and Mode Set Switch 
To select the transmission mode the following procedure should be followed; 
 
Press and hold down the modem set button (before moving the modem mode 
select switch). 
Whilst keeping the mode set button depressed, turn the modem mode switch to 
the appropriate setting. 
Release the modem set button. 
 
Note.  If the modem set button is not depressed whilst the modem mode select 
switch is being moved, the test set may enter an unknown mode. 
 
BELL Modes: 
Switch Setting (Baud)  Full 
Description 
 
1200 equ 
 
 
 
Bell 202 with Equaliser Loopback 
1200 
    Bell 
202 
Main 
Loopback 
300 
    Bell 
103 
 
CCITT Modes: 
Switch Setting (Baud)  Full 
Description 
 
1200 equ 
 
 
 
CCITT V.23 M2 with Equaliser Loopback  
1200 
    CCITT 
V.23 
M2 
Main 
Loopback 
600 
    CCITT 
V.23 
M1 
 
300 
    CCITT 
V.21 
 
Note   Selections at 300 Baud are Originate when the test set is in Instation 
mode and Answer when the test set is in Outstation mode, and a mixture 
when in monitor mode (i.e. test set modem 1 control in Answer mode, test 
set modem 2 reply in Originate mode). This requirement is an automatic 
selection made by the test logic board. The user simply has to select 300 
baud and ITS mode. 
 
666/HE/43100/000  
Page 140 
Issue 9