Assembling and Wiring the Hardware
Specifications and design are subject to change without notice. The content of this document is for information only. The information presented in this document does not form part
of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use.
Publication thereof does neither convey nor imply any license under patent rights or other industrial or intellectual property rights.
Controller modules for the 52/RX.
Since the revision RM420-852B/853B, the upper RJ45 connector provides an RS422 interface (not useable as RS232). On
previous modules this port has no function. 
The middle connector of the three jacks  is  the  interface  to  the  controller  network.  Connect  your  console(s)  to  this  RJ45
jack.  Therefore,  connect  this  port  to  a  PoE  switch,  as  well  as  all  the  fader  and  control  modules  and  TFT  displays.  All
modules  of  this  network  own  an  unique  IP  address,  which  should  not  be  changed.  In  the  system  drawing  above  the
required PoE switch is installed in a power frame. It is also possible to mount the PoE switch next to the console and to
use a separate power supply.
For  configuration  and  controlling  processes,  as  well  as  communication  with  other  DHD  Systems,  the  device  can  be
connected  to  a  PC  or  a  local  network  via  the  lower  RJ45  connector.  The  DHD  system  can  get  any  IP  address  in  this
network.
Use the USB port of the communication controller module if you want to connect directly to the device for maintenance.
General Information
Please  use  CAT5  cables  continuous  for  wiring.  But  DHD  recommends  to  use  CAT6  cables  for  longer  distances.  The
maximum  length  of  the  Ethernet  cable  between  two  modules  of  the  Controller  network  is  100  meters  (for  instance
between  the  Communication  Controller  of  the  DSP  frame  and  a  PoE  switch  or  between  a  PoE  switch  and  52-4050
Controllers  -  that  are  included  in  the  52/XR  fader  and  control  modules.  Use  only  switches  in  the  DHD  network  and  the
controller  network,  which  are  shipped  and/or  recommended  by  DHD  for  the  usage  in  these  networks.  Especially  the
switches must be Unmanaged Switches working with a speed of 100 Mbit/s.
The following switches are tested by DHD and are recommended for the usage in DHD Ethernet networks:
Manufacturer
Type
3com
Superstack 3, Baseline Switch
16 Port 10/100
Ref. 3C16470
3com
Superstack 3, Baseline Switch
24 Port 10/100
Ref. 3C16471