Euphonix 840-07591-04 사용자 설명서
Euphonix System 5 Installation Guide
System 5 Components
53
Rear Panel
Figure 3-21 MA703 Rear Panel
Input Voltage Selector: This red switch allows the unit to operate in either 100/110/
115 VAC or 220/230/240 VAC environments. A fuse must also be changed for 220/
230/240 VAC operation. Units are shipped set and fused for 100/110/115 VAC.
115 VAC or 220/230/240 VAC environments. A fuse must also be changed for 220/
230/240 VAC operation. Units are shipped set and fused for 100/110/115 VAC.
Power Connector (IEC) and Fuse Tray: The IEC power connector accepts standard
IEC power cords. The fuse tray contains both the active and spare fuses.
IEC power cords. The fuse tray contains both the active and spare fuses.
Analog Outputs (male XLR): 24 balanced analog outputs on XLR connectors. Output
level is set from the front panel.
level is set from the front panel.
Auxiliary Analog Outputs (male XLR): Two balanced analog outputs on XLR con-
nectors. Output level can is set from the front panel.
nectors. Output level can is set from the front panel.
AES/EBU Digital Outputs (male XLR): Stereo AES/EBU digital outputs on one XLR
connector. Functions in parallel with the auxiliary S/PDIF output and the two inputs
should not be used simultaneously.
connector. Functions in parallel with the auxiliary S/PDIF output and the two inputs
should not be used simultaneously.
S/PDIF Digital Outputs (RCA): Stereo S/PDIF digital output on one RCA connector.
Functions in parallel with the auxiliary AES/EBU output and the two inputs should not
be used simultaneously.
Functions in parallel with the auxiliary AES/EBU output and the two inputs should not
be used simultaneously.
AES Sync In (female XLR): Master clock input for the converter when using AES as
the Sample Rate Source.
the Sample Rate Source.
AES Sync Thru (male XLR): Outputs the same signal connected to AES Sync In.
Word In (BNC): Master clock input for the converter when using Word Clock as
Sample Rate Source.
Sample Rate Source.
Word Out (BNC): Outputs a Word Clock signal synchronized to the Sample Rate
Source. In the presence of an external Word clock input, this connector provides a
regenerated version of the input signal. Without an external sample rate source, this
connector outputs an internally generated clock signal.
Source. In the presence of an external Word clock input, this connector provides a
regenerated version of the input signal. Without an external sample rate source, this
connector outputs an internally generated clock signal.
MA703
DIGITAL
OUTPUTS
ANALOG
OUTPUTS
MADI