Mitsubishi Electronics QD75MH4 사용자 설명서

다운로드
페이지 838
 
 
 
9 - 76 
MELSEC-Q
 
9   MAJOR POSITIONING CONTROL 
 
(4)  When either of three axes exceeds the speed limit, that axis is controlled with 
the speed limit value.  The speeds of the other axes are limited at the ratios of 
"
Da.8
Command speed". 
(Examples) 
 
Axis 
 
Setting item 
Axis 1 setting 
Axis 2 setting 
Axis 3 setting 
Pr.8
 
Speed limit 
value 
4000.00mm/min 5000.00mm/min 6000.00mm/min 
Da.8
 
Command 
speed 
8000.00mm/min 6000.00mm/min 4000.00mm/min 
 
With the settings shown above, the operation speed in speed control is as 
follows. 
Axis 1: 4000.00 mm/min (Speed is limited by 
Pr.8
). 
Axis 2: 3000.00 mm/min (Speed is limited at ratios in axes 1, 2, and 3 
command speeds). 
Axis 3: 2000.00 mm/min (Speed is limited at ratios in axes 1, 2, and 3 
command speeds). 
(5)  An error "No command speed (error code: 503)" will occur if a current speed  
(-1) is set in "
Da.8
Command speed". 
(6)  The software stroke limit check is not carried out when the control unit is set to 
"degree".