3   SPECIFICATIONS AND FUNCTIONS 
 
Main functions 
Details 
Reference 
section 
Block start (Normal start) 
With one start, executes the positioning data in a random block 
with the set order. 
10.3.2 
Condition start 
Carries out condition judgment set in the "condition data" for 
the designated positioning data, and then executes the "block 
start data".  
When the condition is established, the "block start data" is 
executed. When not established, that "block start data" is 
ignored, and the next point's "block start data" is executed. 
10.3.3 
Wait start 
Carries out condition judgment set in the "condition data" for 
the designated positioning data, and then executes the "block 
start data".  
When the condition is established, the "block start data" is 
executed. When not established, stops the control until the 
condition is established. (Waits.) 
10.3.4 
Simultaneous start 
Simultaneously executes the positioning data having the No. 
for the axis designated with the "condition data". (Outputs 
pulses at the same timing.) 
10.3.5 
Repeated start (FOR loop) 
Repeats the program from the block start data set with the 
"FOR loop" to the block start data set in "NEXT" for the 
designated No. of times. 
10.3.6 
Repeated start (FOR condition) 
Repeats the program from the block start data set with the 
"FOR condition" to the block start data set in "NEXT" until the 
conditions set in the "condition data" are established. 
10.3.7 
H
igh-lev
el positioning control 
Multiple axes simultaneous start 
control 
Starts the operation of multiple axes simultaneously according 
to the pulse output level. 
(Positioning start No. 9004, same as the "simultaneous start" 
above) 
10.5 
JOG operation 
Outputs a pulse to servo amplifier while the JOG start signal is 
ON. 
11.2 
Inching operation 
Outputs pulses corresponding to minute movement amount by 
manual operation to servo amplifier.  
(Performs fine adjustment with the JOG start signal.) 
11.3 
M
anual control 
Manual pulse generator operation 
Outputs pulses commanded with the manual pulse generator to 
servo amplifier. (Carry out fine adjustment, etc., at the pulse 
level.) 
11.4 
 
With the "major positioning control" ("high-level positioning control"), whether or not to 
continuously execute the positioning data can be set with the "operation pattern". 
Outlines of the "operation patterns" are given below. 
 
Da.1
Operation pattern 
Details 
Reference 
section 
Independent positioning control  
(positioning complete) 
When "independent positioning control" is set for the operation 
pattern of the started positioning data, only the designated 
positioning data will be executed, and then the positioning will 
end. 
Continuous positioning control 
When "continuous positioning control" is set for the operation 
pattern of the started positioning data, after the designated 
positioning data is executed, the program will stop once, and 
then the next following positioning data will be executed. 
Continuous path control 
When "continuous path control" is set for the operation pattern 
of the started positioning data, the designated positioning data 
will be executed, and then without decelerating, the next 
following positioning data will be executed. 
9.1.2