Acu-Rite 1604 사용자 설명서

다운로드
페이지 20
13
Troubleshooting
Problem
Possible Solution
No outdoor sensor
reception
  
no bars
•  Relocate the display unit and/or the 3-in-1 sensor.  
The units must be within 330 ft (100 m) of each other.
•  Make sure both units are placed at least 3 feet (.9 m) 
away from electronics that may interfere with the wireless 
communication (such as TVs, microwaves, computers, etc). 
•  Use standard alkaline batteries (or lithium batteries in 
sensor when temperature is below -4ºF/-20ºC). Do not use 
heavy duty or rechargeable batteries. NOTE: It may take 
up to 20 minutes for display unit and sensor to synchronize 
after batteries are replaced.
•  Synchronize the units:
1.  Bring both the sensor and display unit indoors and 
remove at least one battery from each.
2. Make sure the A-B-C switch on both units match.
3. Reinstall the battery in the outdoor sensor. 
4. Reinstall battery into the display unit.
5.  Let the units sit within a couple feet of each other for 
about 20 minutes to gain a strong connection. 
Outdoor 
 temperature
is flashing or   
showing dashes
Flashing of the outdoor temperature may be an indication of 
wireless interference:
•  Make sure the A-B-C switch in the battery compartments of 
both the display unit and sensor are switched to the same 
letter. You may choose A, B or C; but both units must match 
to sync up. Sometimes changing to a different channel can 
help.
Inaccurate forecast
•  Weather Forecast icon predicts conditions for the next 12 
to 24 hours, not current conditions.
•  Has Learning Mode icon disappeared from the display 
unit? Learning Mode must complete before forecast and 
pressure will be accurate.
•  Allow unit to run continuously for 33 days. Battery removal 
or resetting the display unit will restart Learning Mode. 
After 14 days, forecast should be fairly accurate, however 
Learning Mode calibrates for a total of 33 days.