Hitachi hitachi series inverter 사용자 설명서

다운로드
페이지 99
 
24 
 
Recommended ferrule 
 
For safe wiring and reliability, it is recommended to use following ferrules. 
 
Wire size 
mm
2
 (AWG) 
Model name of 
ferrule * 
L [mm] 
Φd [mm] 
ΦD [mm] 
0.25 (24) 
AI 0.25-8YE 
12.5 
0.8 
2.0 
0.34 (22) 
AI 0.34-8TQ 
12.5 
0.8 
2.0 
0.5 (20) 
AI 0.5-8WH 
14 
1.1 
2.5 
0.75 (18) 
AI 0.75-8GY 
14 
1.3 
2.8 
 
* Supplier: Phoenix contact 
Crimping pliers: CRIPMFOX UD 6-4 or CRIMPFOX ZA 3 
 
 
How to connect? 
 
(1) Push down an orange actuating lever by a slotted screwdriver (width 2.5mm max.). 
(2) Plug in the conductor. 
(3) Pull out the screwdriver then the conductor is fixed. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Φ
Φ
Push down an 
orange actuating 
lever. 
2.5mm 
Plug in the 
conductor. 
Pull out the 
screwdriver to fix 
the conductor.