Hitachi hitachi series inverter 사용자 설명서
24
Recommended ferrule
For safe wiring and reliability, it is recommended to use following ferrules.
Wire size
mm
2
(AWG)
Model name of
ferrule *
L [mm]
Φd [mm]
ΦD [mm]
0.25 (24)
AI 0.25-8YE
12.5
0.8
2.0
0.34 (22)
AI 0.34-8TQ
12.5
0.8
2.0
0.5 (20)
AI 0.5-8WH
14
1.1
2.5
0.75 (18)
AI 0.75-8GY
14
1.3
2.8
* Supplier: Phoenix contact
Crimping pliers: CRIPMFOX UD 6-4 or CRIMPFOX ZA 3
How to connect?
(1) Push down an orange actuating lever by a slotted screwdriver (width 2.5mm max.).
(2) Plug in the conductor.
(3) Pull out the screwdriver then the conductor is fixed.
(2) Plug in the conductor.
(3) Pull out the screwdriver then the conductor is fixed.
8
L
Φ
d
Φ
D
Push down an
orange actuating
lever.
orange actuating
lever.
2.5mm
Plug in the
conductor.
conductor.
Pull out the
screwdriver to fix
the conductor.