Hitachi hitachi series inverter 사용자 설명서

다운로드
페이지 99
 
WJ200 Inverter Specifications, continued… 
 
Item 
Three-phase 400V class Specifications 
WJ200 inverters, 400V models 
004HF 007HF 015HF 022HF 030HF  040HF 
VT 0.75  1.5  2.2 3.0 4.0 5.5 
kW 
CT 0.4 0.75 1.5 2.2 3.0 4.0 
VT 
1 2 3 4 5 7.5 
Applicable motor size 
HP 
CT 
1/2 1 2 3 4 5 
VT 1.3  2.6  3.5 4.5 5.7 7.3 
380V 
CT 1.1  2.2  3.1 3.6 4.7 6.0 
VT 1.7  3.4  4.4 5.7 7.3 9.2 
Rated capacity (kVA) 
480V 
CT 1.4  2.8  3.9 4.5 5.9 7.6 
Rated input voltage 
Three-phase: 400V-15% to 480V +10%, 50/60Hz 
±5% 
Rated output voltage 
Three-phase: 400 to 480V (proportional to input voltage) 
VT 2.1 4.1 5.4 6.9 8.8 11.1 
Rated output current (A) 
CT 1.8  3.4  4.8 5.5 7.2 9.2 
Starting torque 
200% at 0.5Hz 
Without resistor 
100%:
50Hz 
50%:
60Hz 
70%:
≤ 50Hz 
50%:
≤ 60Hz 
20%:
≤ 50Hz 
20%:
≤ 60Hz
 
Braking 
With resistor 
150% 
 
DC braking 
Variable operating frequency, time, and braking force 
kg 1.5  1.6  1.8 1.9 1.9 2.1 
Weight 
lb 3.3  3.5  4.0 4.2 4.2 4.6 
 
 
Item 
Three-phase 400V class Specifications 
WJ200 inverters, 400V models 
055HF 075HF 110HF 150HF 
 
 
VT 7.5  11  15  18.5   
 
kW 
CT 5.5  7.5  11  15   
 
VT 
10 15 20 25   
 
Applicable motor size 
HP 
CT 7.5  10  15  20   
 
VT 11.5 15.1 20.4 25.0   
 
380V 
CT 9.7  11.8 15.7 20.4   
 
VT 14.5 19.1 25.7 31.5   
 
Rated capacity (kVA) 
480V 
CT 12.3 14.9 19.9 25.7   
 
Rated input voltage 
Three-phase: 400V-15% to 480V +10%, 50/60Hz 
±5% 
Rated output voltage 
Three -phase: 400 to 480V (proportional to input voltage) 
VT 17.5 23.0 31.0 38.0   
 
Rated output current (A) 
CT 14.8 18.0 24.0 31.0   
 
Starting torque 
200% at 0.5Hz 
Without resistor 
20%:
50Hz 
20%:
60Hz 
 
 
Braking 
With resistor 
150% 
 
 
DC braking 
Variable operating frequency, time, and braking force 
kg 3.5 3.5 4.7 5.2   
 
Weight 
lb 7.7  7.7 10.4 11.5