HP E2910-24G-PoE+ al Switch + Care Pack J9146A#ABB-BNDL 데이터 시트

제품 코드
J9146A#ABB-BNDL
다운로드
페이지 11
5
HP 2910 al Switch Series
Specifications
HP 2910-24G al Switch (J9145A)
HP 2910-48G al Switch (J9147A)
Ports
20 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u
Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Media Type: Auto-MDIX;
Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only
4 dual-personality ports; each port can be used as either an RJ-45
10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type
100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or as a mini-GBIC slot
(for use with mini-GBIC transceivers)
1 RJ-45 serial console port
Supports a maximum of 4 10-GbE ports, with optional module
44 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u
Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Media Type: Auto-MDIX;
Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only
4 dual-personality ports; each port can be used as either an RJ-45
10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type
100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or as a mini-GBIC slot
(for use with mini-GBIC transceivers)
1 RJ-45 serial console port
Supports a maximum of 4 10-GbE ports, with optional module
Physical characteristics
Dimensions
14.4(d) x 17.4(w) x 1.73(h) in. (36.58 x 44.2 x 4.4 cm) (1U height)
14.4(d) x 17.42(w) x 1.73(h) in. (36.58 x 44.25 x 4.4 cm) (1U height)
Weight
10.92 lb. (4.95 kg)
11.2 lb. (5.08 kg)
Memory and processor
Processor
Dual ARM1156T2S @ 515 MHz, 4 MB flash, 1 GB compact flash, 512 MB
SDRAM; packet buffer size: 6 MB
Dual ARM1156T2S @ 515 MHz, 4 MB flash, 1 GB compact flash, 512 MB
SDRAM; packet buffer size: 6 MB
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware
included); horizontal surface mounting only
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware
included); horizontal surface mounting only
Performance
1000 Mb Latency
< 2.9 µs (FIFO 64-byte packets)
< 2.9 µs (FIFO 64-byte packets)
10 Gbps Latency
< 1.3 µs (FIFO 64-byte packets)
< 1.3 µs (FIFO 64-byte packets)
Throughput
up to 95 million pps (64-byte packets)
up to 131 million pps
Switching capacity
128 Gbps
176 Gbps
Routing table size
2000 entries
2000 entries
MAC address table size
16000 entries
16000 entries
Environment
Operating temperature
32°F to 131°F (0°C to 55°C)
32°F to 131°F (0°C to 55°C)
Operating relative humidity
15% to 95% @ 104°F (40°C), noncondensing
15% to 95% @ 104°F (40°C), noncondensing
Nonoperating/Storage temperature
-40°F to 158°F (-40°C to 70°C)
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage relative humidity
15% to 95% @ 149°F (65°C), noncondensing
15% to 95% @ 149°F (65°C), noncondensing
Altitude
up to 10,000 ft. (3 km)
up to 10,000 ft. (3 km)
Acoustic
Power: 53.5 dB, Pressure: 39.4 dB; DIN 45635T.19 per ISO 7779
Power: 53.5 dB, Pressure: 39.4 dB; DIN 45635T.19 per ISO 7779
Electrical characteristics
Achieved Miercom Certified Green Award
Description
The switch automatically adjusts to any voltage between 100-127 and 200-240
volts and either 50 or 60 Hz
The switch automatically adjusts to any voltage between 100-127 and 200-240
volts and either 50 or 60 Hz
Maximum heat dissipation
279 BTU/hr (295 kJ/hr)
356 BTU/hr (376 kJ/hr)
Voltage
100-127/200-240 VAC
100-127/200-240 VAC
Current
1.7/0.9 A
2.1/1.1 A
Idle power
49 W
64 W
Maximum power rating
82 W
105 W
Frequency
50/60 Hz
50/60 Hz
Notes
Idle power is the actual power consumption of the device with no ports
connected.
Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure with fully
loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules
populated.
Idle power is the actual power consumption of the device with no ports
connected.
Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure with fully
loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules
populated.
Safety
EN 60950/IEC 60950; CAN/CSA 22.2 No. 60950; EN 60825; UL 60950
EN 60950/IEC 60950; CAN/CSA 22.2 No. 60950; EN 60825; UL 60950
Emissions
FCC part 15 Class A; EN 55022/CISPR-22 Class A; VCCI Class A
FCC part 15 Class A; EN 55022/CISPR-22 Class A; VCCI Class A
Immunity
EN
EN 55024, CISPR 24
EN 55024, CISPR 24
ESD
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated
IEC 61000-4-3; 3 V/m
IEC 61000-4-3; 3 V/m
EFT/Burst
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge
IEC 61000-4-5; 1 kV / 2 kV AC, 1 kV signal, 0.5 kV DC
IEC 61000-4-5; 1 kV / 2 kV AC, 1 kV signal, 0.5 kV DC
Conducted
IEC 61000-4-6; 3 V
IEC 61000-4-6; 3 V
Power frequency magnetic field
IEC 61000-4-8; 1 A/m
IEC 61000-4-8; 1 A/m
Voltage dips and interruptions
IEC 61000-4-11; > 95% reductions, 0.5 period; 30% reduction, 25 periods
IEC 61000-4-11; > 95% reductions, 0.5 period; 30% reduction, 25 periods
Harmonics
IEC 61000-3-2
IEC 61000-3-2