Nortel Networks 411-2021-111 사용자 설명서

다운로드
페이지 98
 
DualMode Metrocell Cell Site Specifications
 
 7-5
 
DMS-MTX DualMode Metrocell Cell Site Description
 
Earthquake
Meet earthquake requirements of Zone 1 
and Zone 2 as defined by Bellcore 
TR-NWT-000063
Fixed equipment anchorage.
Thermal dissipation for Metrocell RF Frame: 
 
Regulatory
Electromagnetic Emissions
 
Cell site equipment complies with the following Regulatory Specification:
FCC part 22 for 800 MHz frequency
FCC part 15 Class B for cell site with Universal CE Frame and Metro RF 
Frame (except for the ICRM, CSM, HSMO and ACU shelves located on 
the Universal CE Frame)
DOC RSS-128 Issue 1.0 Dual Mode Capability in Canada
|
 
Radiated Emissions
 
Cell site equipment complies with the following Regulatory Specification:
FCC Part 22 for 800 MHz frequency
FCC Part 15 Class B for cell site with Universal CE Frame and Metro RF 
Frame (except for the ICRM, CSM, HSMO and ACU shelves located on 
the Universal CE Frame)
Bell Canada Design Standard TAD 8465 of Bellcore TR-NWT-001089 in 
10 kHz to 30 MHz and 1 GHz to 10 GHz range for radiated emission
 
Telecom Compliance
 
Cell site equipment complies with the following Regulatory Specification:
CS03, Issue 7, Part 2 (Table 1: Digital Interface Requirement, Type IV)
FCC Part 68 (TSB31, Table 4.5-2: Test Requirement Matrix)
 
Component
Dissipation per 
unit
Maximum 
number of units
Total 
dissipation
 
TRU
27 W
24
648 W
PA
89 W
24
2136 W
Combiner (-4.5 dB)
21 W
24
504 W
Duplexer (-0.7 dB)
9.3 W
3
28 W
Total
3.3 KW