Removing the Collector Bag 
 
  
CAUTION 
Wearing a particle mask/respirator for 
protection against fine dust particles during 
cleaning is highly recommended. 
 
1.  Disconnect the machine from the power 
source, unplug. 
 
2.  Remove the collector bag by pushing the 
ring of the collector bag upwards and pulling 
the bag out at an angle.   
 
3.  Empty the contents into an appropriate 
container. 
 
4.  Turn the bag inside out and clean.   
 
5.  Turn the bag outside in and insert into the 
housing.   
 
 
  
WARNING 
To reduce the risk of injury from moving 
parts, always keep inlet connected to a 
flexible hose.  Failure to comply may result 
in serious injury! 
 
 
Electrical Connections 
 
  
WARNING 
All electrical connections must be done by a 
qualified electrician.  All adjustments or 
repairs must be done with the dust collector 
disconnected from the power source, 
unplugged.  Failure to comply may result in 
serious injury! 
 
The DC-650A dust collector is rated at 
115/230V, Prewired 115V.  Use a plug and 
outlet rated at least 20 amps.  The circuit for the 
machine should also be protected by at least a 
20 amp circuit breaker or fuse.  Keep in mind 
that a circuit being used by other machines, 
tools, lights, heaters, etc. at the same time will 
add to the electrical load.  A dedicated circuit to 
the dust collector will give you the best results 
since dust collectors are generally used at the 
same time other tools are running. 
 
Before hooking up to the power source, make 
sure that the switch is in the off position. 
 
 
 
Turning the Machine On & Off 
 
Before hooking up to the power source, make 
sure that the switch is in the off position. 
 
The dust collector can be turned on by flipping 
the start switch up.  Flip the switch down to turn 
the dust collector off.  There is a removable key 
that can be used to lock the machine in the 
“OFF” position. 
 
 
Maintenance 
 
  
WARNING 
Never perform maintenance on this machine 
before turning switch off and removing plug 
from power source, unplug. 
Failure to comply may cause serious injury! 
 
 
Motor 
 
Inspect the motor fan and blow out (with low 
pressure air hose) or vacuum any accumulation 
of foreign material in order to maintain normal 
motor ventilation.   
 
 
Connecting the Dust collector to a 
Machine 
 
Use the proper type hose to connect the dust 
collector to the machine being operated.  Dryer 
vent hose is not acceptable for this purpose.  
Contact your nearest JET distributor for the full 
line of JET Dust Collector Hoses and 
Accessories.  Customize your installation and 
obtain maximum performance with JET's dust 
hoods, hoses, clamps, fittings, and blast gates. 
 
You can also purchase the JET “Dust Collection 
How-To-Book”
 stock # JW1050 through your 
JET Distributor.   
 
 
Grounding the Dust Collection System 
 
The dust collection system includes the dust 
collector and the hose, or duct work you use to 
connect the tools.  The dust collector is grounded 
though the ground wire in the cord.  The hose or 
duct work you use to connect the tool to the dust 
collector must also be grounded.  To assist in 
grounding your system you can purchase the JET 
“Dust Collector Grounding Kit” stock # JW1053, 
and also the JET “Dust Collection How-To-Book” 
stock # JW1050 through your JET Distributor.