John Deere AC2-20E 사용자 설명서

다운로드
페이지 40
 Portable Electric Air Compressor Manual 
       
 
 
 
              15
MAINTENANCE INSTRUCTIONS
Read  the  instruction  manual  before  performing  maintenance.    The  follow-
ing  procedures  must  be  performed  when  stopping  the  air  compressor  for 
maintenance or service.
  1.  Turn off air compressor.  
  2.  Disconnect Power Cord from main power supply.
  3.  Open all drains.
  4.  Wait for the air compressor to cool before starting service.
WARNING
RISK OF BODILY INJURY!
Never  assume  the  air 
compressor is safe to work 
on  just  because  it  is  not 
operating.  It could restart 
at any time!
*The pump oil must be changed after the first 50 hours of operation and every 
200 hours or 3 months, whichever comes first.
Every two years, an Authorized Service Technician should check the check 
valve, intake valves and delivery valves.
AC Ele. Maintenance Chart
MAINTENANCE CHART
PROCEDURE
DAILY
WEEKLY
MONTHLY
200 HOURS
Check pump oil level
X
Oil leak inspection
X
Drain condensation in air tank (s)
X
Inspect guards/covers
X
Check for unusual noise/vibration
X
Check for air leaks
X
Clean exterior of compressor
X
Inspect air filter
X
Inspect belt
X
Check safety relief valve
X
Change pump oil *
X
Replace air filter
X