OPTIONAL ACCESSORIES
1196 6- inch Dyna-Coupler (includes Pouch)
2200  Series Carrying Bag
2205 EMS Marker Locating Accessory (single frequencies)
2206 EMS Marker Locating Accessory (all frequencies)
3005 1 inch Dyna-Coupler
3011 Inductive Probe
3019 3- inch Dyna-Coupler Kit (includes 9011 Coupler Cable and Pouch)
3229 Active Duct Probe (sonde)
9011 Coupler Cable
9023 Probe Cable
9043 Ground Extension Cable
PAIR IDENTIFICATION
Receiver Setup
Press 
 to turn the Receiver on.
Press          to select Tone mode 
 .
Connect the inductive probe to Receiver accessory jack using probe cable.
Press 
 to select the highest toning frequency  (200 kHz).
Insert Probe into the bundle of pairs (or group, if known) and press 
 .
Next, divide the pairs into two bundles and insert the Probe into each of the
bundles and observe the numeric display.  The bundle with the highest
reading will contain the target pair. Continue by dividing the bundle with
the target pair into two parts and checking each part for the highest signal.
In this way the target pair will be isolated.