9-3-2  Vibration suppression measures 
 
If vibration (machine resonance) occurs, it can be suppressed by lowering the speed loop gain (VGN1). 
However, cutting precision and cycle time will be sacrificed. (Refer to "9-2-2 Speed loop gain".) Thus, try 
to maintain the VGN1 as high as possible, and suppress the vibration using the vibration suppression 
functions.  
If the VGN1 is lowered and adjusted because vibration cannot be sufficiently suppressed with the 
vibration suppression functions, adjust the entire gain (including the position loop gain) again. 
<Examples of vibration occurrence> 
• A fine vibration is felt when the machine is touched, or a groaning sound is heard. 
• Vibration or noise occurs during rapid traverse. 
 
 
POINT
 
Suppress the vibration using the vibration suppression functions, and maintain 
the speed loop gain (SV005 (VGN1)) as high as possible. 
 
(1) Notch 
filter 
The notch filter operates at the set frequency. Measure the resonance frequency with the current 
feedback analog output function, and set that frequency in SV038 or SV046. 
If the notch filter is set to a particularly low frequency, vibration may occur initially due to another 
resonance frequency that existed latently. If the notch filter's depth compensation (SV033 (nfd1, 
nfd2)) is adjusted so that the filter does not operate unless necessary, the servo control will 
stabilize. 
Notch filter 3 (SV033 (bit4)) is a filter with frequency fixed to 1125Hz, and has no depth compensation. 
  <Setting method> 
1.  Set the resonance frequency in the machine resonance suppression filter frequency (SV038 
(FHz1), SV046 (FHz2)).  
2.  If the machine starts to vibrate at another frequency, raise (make shallower) the machine 
resonance suppression filter depth compensation value (SV033 (SSF2.nfd)), and adjust to the 
optimum value at which the resonance can be eliminated. 
3.  If the vibration cannot be removed completely, use another vibration suppression control (notch 
filter 3, jitter compensation). 
No. 
Abbrev. 
Parameter name 
Explanation 
Setting range
SV038 
FHz1 
Notch filter frequency 
Set the vibration frequency to suppress if machine vibration occurs. 
(Valid at 36 or more) When not using, set to "0". 
0 to 4500 
(Hz) 
SV046 
FHz2 
Notch filter frequency 
Set the vibration frequency to suppress if machine vibration occurs. 
(Valid at 36 or more) When not using, set to "0". 
0 to 4500 
(Hz) 
SV033 
SSF2 
Servo function  
 
 
 
selection 2 
 F 
E
D
C
B
A
9
8
7
6
1
0
 
 
  
  
zup
dis 
nfd2 nf3 nfd1   
 
 
 
 
 
  
 
 
bit  Meaning when "0" is set 
Meaning when "1" is set 
 
 
 
 
 
Set the filter depth for Notch filter 1 (SV038). 
 
  
 
 
nfd1
Value  
Deep
 
000
001
010
011
100
101 110 111 
Shallow
 
  
 
 
Depth 
(dB)
-
-18.1 -12.0 -8.5 -6.0 -4.1 -2.5 -1.2  
 
 
 
 
 
nf3 Notch filter 3 stop 
Notch filter 3 start (1125Hz) 
 
 
 
 
 
Set the operation frequency of Notch filter 2 (SV046). 
 
  
 
 
nfd2
Value  
Deep
 
000
001
010
011
100
101 110 111 
Shallow
 
  
 
 
Depth 
(dB)
-
-18.1 -12.0 -8.5 -6.0 -4.1 -2.5 -1.2