Mitsubishi Electronics MDS-R 사용자 설명서

다운로드
페이지 362
 
Appendix 4. EMC Installation Guidelines 
 
 
 
 
 
A4 - 7
Appendix 4-5-4  Servo/spindle motor feedback cable 
 
Use a shield pair cable for feed back cable of the servo motor to earth on NC side (inside the control 
panel.) Mounting a ferrite core directly behind the unit connector is also effective in suppressing noise. 
 
 
Control panel 
To drive unit
 
Cannon connector
 
Batch shield pair cable
 
 
Feed back cable for servomotor