Appendix 5  Instruction Manual for Compliance with UL/c-UL Standard 
 
 
 
 
 
A5 - 2
Instruction Manual for Compliance with UL/c-UL Standard 
(MDS-R Series) 
The instructions of UL/c-UL listed products are described in this manual. 
The descriptions of this manual are conditions to meet the UL/c-UL 
standard for the UL/c-UL listed products. To obtain the best performance, 
be sure to read this manual carefully before use. 
To ensure proper use, be sure to read specification manual, connection 
manual and maintenance manual carefully for each product before use. 
 
Appendix 5-1  Operation surrounding air ambient 
temperature 
The recognized operation ambient temperatures of each unit are as 
shown in the table below. The recognized operation ambient 
temperatures are the same as an original product specification for all of 
the units. 
Classification Unit 
name 
Operation ambient 
temperature 
Power supply unit 
0~55
C 
Servo, Spindle drive unit 
0~55
C 
Option unit, Battery unit 
0~55
C 
AC Servo/ 
Spindle system 
Servo motor, Spindle motor  0~40
C 
 
Appendix 5-2  Notes for AC servo system 
Appendix 5-2-1  General Precaution 
It takes 10 minutes to discharge the bus capacitor. 
When starting wiring or inspection, shut the power off and wait for more 
than 15 minutes to avoid a hazard of electrical shock. 
 
Appendix 5-2-2  Installation 
MDS-R Series have been approved as the products which have been 
installed in the electrical enclosure. 
The minimum enclosure size is based on 150 percent of each MDS-R 
Series combination. And also, design the enclosure so that the ambient 
temperature in the enclosure is 55
C (131F) or less, refer to the 
specifications manual. 
 
Appendix 5-2-3  Short-circuit ratings 
Suitable for use in a circuit capable of delivering not more than 100 kA 
rms symmetrical amperes, 500 volts maximum. 
 
Appendix 5-2-4  Peripheral devices 
To comply with UL/c-UL Standard, use the peripheral devices which 
conform to the corresponding standard. 
- Circuit Breaker, Fuses, Magnetic Contactor and AC Reactor 
Applicable  
power supply unit 
Circuit Breaker 
Fuse 
Class K5 
Magnetic  
Contactor (AC3)
MDS-R-V1-20 NF30 
15A  30A 
S-N12 
MDS-R-V1-40 NF30 
20A  40A 
S-N18 
MDS-R-V1-60 
NF30 30A 
60A 
S-N20  
MDS-R-V1-80 NF30 
30A  60A 
S-N25 
MDS-R-V2-2020 NF30 
20A 
40A 
S-N18 
MDS-R-V2-4040 NF30 
30A 
60A 
S-N20 
MDS-R-V2-6040 NF30 
30A 
80A 
S-N20 
MDS-R-V2-6060 NF50 
40A 
80A 
S-N25 
MDS-R-V2-8040 NF50 
40A 
80A 
S-N25 
MDS-R-V2-8060 NF50 
40A 
80A 
S-N25 
MDS-R-V2-8080 NF50 
40A 
80A 
S-N25 
<Notice> 
- For installation in United States, branch circuit protection must be 
provided, in accordance with the National Electrical Code and any 
applicable local codes. 
- For installation in Canada, branch circuit protection must be 
provided, in accordance with the Canadian Electrical Code and any 
applicable provincial codes. 
 
 
Appendix 5-2-5  Field Wiring Reference Table for Input and Output 
Use the Tyco Electronics Corporation "Dynamic Series" connectors to 
wire the input and output terminals of MDS-R Series. Crimp the pins with 
the crimping tool recommended by the manufacturer.  
This wire size is each unit maximum rating. The selection method is 
indicated in each specification manual. (See Manual: No. BNP-C3045) 
 
(1) Input 
CN30 (L1, L2, L3) 
 
Capacity 
[kW]  20 40 60 80 
 
 
 
 
Wire Size (AWG) 
/Temp Rating  Note 1
#14/75
C #14/75C #12/75C #12/75C
 
 
 
 
Earth Wire Size 
(AWG) 
#14/75
C #14/75C #12/75C #12/75C
 
Capacity 
[kW]  2020 4040 6040 6060 
 
 
 
 
Wire Size (AWG) 
/Temp Rating  Note 1
#14/75
C #14/75C #12/75C #12/75C
 
 
 
 
Earth Wire Size 
(AWG) 
#14/75
C #14/75C #12/75C #12/75C
 
Capacity 
[kW]  8040 8060 8080 
 
 
 
 
 
Wire Size (AWG) 
/Temp Rating  Note 1
#12/75
C #10/75C #10/75C
 
 
 
 
 
Earth Wire Size 
(AWG) 
#12/75
C #10/75C #10/75C
 
 
(2) Output
 
CN31L, CN31M (U, V, W) 
 
Capacity [kW] 
20 
40 
60 
80 
 
 
 
 
Wire Size (AWG) 
/Temp Rating  Note 1
#14/75
C #14/75C #12/75C #12/75C
 
 
 
 
Earth Wire Size 
(AWG) 
#14/75
C #14/75C #12/75C #12/75C
 
 
Appendix 5-2-6  Motor Over Load Protection  
Servo drive unit MDS-R-V1 and V2 series have each solid-state motor 
over load protection.
 
(The motor full load current is the same as rated 
current.) 
When adjusting the level of motor over load, set the parameter as 
follows. 
MDS-R-V1/V2 
Parameter
No. 
Parameter
abbr. 
Parameter 
name 
Setting 
Procedure 
Standard
setting 
value
Setting
range
SV021 OLT 
Overload
time 
constant 
Set the time 
constant for 
overload detection. 
(Unit: 1 second.) 
60s 1 
to 
300s 
SV022 OLL 
Overload
detection 
level 
Set the overload 
current detection 
level with a 
percentage (%) of 
the stall rating. 
150% 1 
to 
500%
 
Appendix 5-2-7  Flange of servo motor 
Mount the servo motor on a flange which has the following size or 
produces an equivalent or higher heat dissipation effect: 
Servo Motor 
Flange size 
(mm)
HF, HC 
HC-MF, HA-FF 
150x150x6 ---  <100 
250x250x6 --- 
200, 
300 
250x250x12 
0.5 to 1.5 kW 
400, 600 W 
300x300x12 --- 
750 
300x300x20 
2.0 to 3.5 kW 
---