Specifications
Amperes Input at AC Balanced
Rated Load Output,
50/60 Hz, Single-Phase
Rated
Welding Output
PFC**
200 V
230 V
460 V
575 V
KVA
KW
Amp
Range
Max
OCV
IP
Rating
NEMA Class II
(40) – 250
No
PFC
106
(4.6*)
92
(4*)
46
(2*)
37
(1.6*)
21
(0.89*)
11.4
(0.68*)
Amperes, 30 Volts
AC, 40% Duty
Cycle
With
PFC
PFC
76
66
33
26
15.2
11.4
5–310 A
80 V
21
*While idling
**Power Factor Correction
**Power Factor Correction
Rated
Amperes Input at AC Balanced
Rated Load Output,
50/60 Hz, Single-Phase
Rated
Welding
Output
PFC
**
200
V
220
V
230
V
260
V
380
V
415
V
460
V
520
V
575
V
KVA
KW
Amp
Range
Max
OCV
IP
Rating
NEMA
Class I
(60) – 200
No
PFC
85
(4.6*)
77
(4.2*)
74
(4*)
65
(3.5*)
45
(2.4*)
41
(2.2*)
37
(2*)
33
(1.8*)
30
(1.6*)
17
(0.9*)
8.3
(0.7*)
Amperes,
28 Volts
AC, 60%
Duty Cycle
With
PFC
PFC
55
(57*)
64
(51*)
48
(49*)
48
(49*)
37
(30*)
34
(27*)
24
(25*)
48
(49*)
19
(20*)
11
(11*)
8.3
(0.6*)
5–310 A
80 V
21
*While idling
**Power Factor Correction
**Power Factor Correction
3-2.
Volt-Ampere Curves
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding power source. Curves
of other settings fall between the
curves shown.
minimum and maximum voltage
and amperage output capabilities of
the welding power source. Curves
of other settings fall between the
curves shown.
ssb1.1 10/91 – SB-116 199 / SB-116 200
A. DC Mode
B. AC Mode