Fujitsu FP-410 사용자 설명서

다운로드
페이지 60
50 
<Drawer connection 1> 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Notes: 
        1. Use a shielded drawer cable. 
    2. Two drives cannot be driven simultaneously. 
        3. The drawer on/off time must be specified using t1 and t2 in   
         the pulse generation command (ESC p m t1 t2). 
        4. The drawer drive duty must be as follows: 
                  ON-time/(ON-time + OFF-time) ≤ 0.2 
        5. The drawer power must always be supplied from the printer 
         power supply unit via connector pin 4. 
        6. The resistance of the drawer kick solenoid must be at least 24 
Ω.  
         If a solenoid with a lower resistance is used, the solenoid might 
be destroyed by over current.   
APPENDIX 
Printer 
Cable 
Drawer
Drawer kick solenoid 
(24 
Ω minimum) 
Drawer 
open/close 
switch