Sharp AR-M205 사용자 설명서

다운로드
페이지 96
66
TROUBLESHOOTING
B. Misfeed in the fusing area
1
Push gently on both ends of the front 
cover.
2
Turn the roller rotating knob in the 
direction of the arrow.
3
Carefully remove the misfed paper. 
Lower the fusing unit release levers to 
allow easier removal. Return the 
release levers to their operating 
positions.
Be careful not to tear the 
misfed paper during 
removal.
4
Lift the fusing unit release lever.
5
Close the front cover and side cover.
The misfeed indicator 
(
) will go out.
The fusing unit is hot. Do not touch 
the fusing unit when removing misfed 
paper. Doing so may cause a burn or 
injury.
• Do not touch the photoconductive drum 
(green portion) when removing the misfed 
paper. Doing so may damage the drum and 
cause smudges on copies.
• Be careful about unfixed toner on the 
misfed paper not to soil your hands or 
clothes.
Roller rotating knob
Fusing unit 
release lever
Warning
Caution
• When closing the front cover, press on both 
ends.
• When closing the side cover, press on the 
handle.
• If the misfeed indicator (
) does not stop 
blinking, check for torn pieces of paper in 
the machine.
Note