OKI OL610EPS 사용자 설명서

다운로드
페이지 182
%Appendix B LOCALTALK (RS422) SERIAL INTERFACE 
(OL610e/PS only)
                                                                                                                                                
Appendix B LOCALTALK (RS422) SERIAL INTERFACE (OL610e/PS only)
1) Connector
• Printer side : 8-pin mini DIN receptacle Type TCS7187-01-201 (made by HOSHIDEN) or equivalent • 
Cable side : 8-pin mini DIN plug Type TCP7180-01-110 (made by HOSHIDEN) or equivalent
2) Cable
• To be shielded cable • Cable length LocalTalk Defined max. length : 1,000 ft. (305 m)--maximum length 
for a LocalTalk network. Recommended max. length : 10 ft. (3 m) (For noise prevention) RS422 : 6 ft. 
(1.8 m) max.
3) Interface signal
Pin No.
Signal Name
Abbreviation
Signal Direction
Description
1
(Not used)
2
Sync. signal
SYNC
 PR
(Not used)
3
Transmit data 
minus
TxD-
 PR
Transmit data minus 
polarity
4
Signal ground
SG
Signal ground
5
Receive data 
minus
RxD-
PR
Receive data minus 
polarity
6
Transmit data 
plus
TxD+
 PR
Transmit data plus 
polarity
7
(Not used)
8
Receive data 
plus
RxD+
 PR
Receive data plus 
polarity
• Connector Pin Arrangement
(As viewed from the cable side)
4) Signal level
Differential output : ±5V Differential input : ±7V
5) Interface circuit
a) Receiving circuit
OKI OL600/610ex (96-01-18