Toshiba e-STUDIO4500c/5500c 사용자 설명서

다운로드
페이지 1120
August, 2006 
SERVICE PROGRAM TABLES 
5-187 
9407 Environ 
Cntrl 
001 
Environ Cntrl 
Enable/disables the Peltier unit. 
[0 to 1 / 1] 
0: Disabled 
1: Enabled 
004 Op 
Humidity 
Factory Use Only. Do Not Touch in the field. 
005 Stop 
Humidity 
Factory Use Only. Do Not Touch in the field. 
006 
Op On Time 
Factory Use Only. Do Not Touch in the field. 
007 
Op Off Time 
Factory Use Only. Do Not Touch in the field. 
IMPOTANT:
 
  As a general rule, keep this SP mode disabled. 
Enable this SP mode ONLY WHEN: 
1.  The temperature in the room is low, and 
2.  There is condensation on the drum or charge roller, and 
3.  The images on the printouts are blurry 
 
  To enable the Peltier unit: 
1.  Set this SP mode to a value of 1, and 
2. Turn OFF the AOF function in User Program Mode. 
NOTE:  There are some environmental conditions that the Peltier unit needs to 
operate (ex: humidity of 60% or higher). If the Peltier unit does not 
operate after you do the above steps, it is because these conditions are 
not satisfied. 
 
  When the AOF function is turned OFF, the machine is not in compliance with the 
Energy Star requirements.