SERVICE PROGRAM TABLES
5-187
9407 Environ
Cntrl
001
Environ Cntrl
Enable/disables the Peltier unit.
[0 to 1 / 1]
0: Disabled
1: Enabled
[0 to 1 / 1]
0: Disabled
1: Enabled
004 Op
Humidity
Factory Use Only. Do Not Touch in the field.
005 Stop
Humidity
Factory Use Only. Do Not Touch in the field.
006
Op On Time
Factory Use Only. Do Not Touch in the field.
007
Op Off Time
Factory Use Only. Do Not Touch in the field.
IMPOTANT:
•
As a general rule, keep this SP mode disabled.
Enable this SP mode ONLY WHEN:
1. The temperature in the room is low, and
2. There is condensation on the drum or charge roller, and
3. The images on the printouts are blurry
1. The temperature in the room is low, and
2. There is condensation on the drum or charge roller, and
3. The images on the printouts are blurry
•
To enable the Peltier unit:
1. Set this SP mode to a value of 1, and
2. Turn OFF the AOF function in User Program Mode.
2. Turn OFF the AOF function in User Program Mode.
NOTE: There are some environmental conditions that the Peltier unit needs to
operate (ex: humidity of 60% or higher). If the Peltier unit does not
operate after you do the above steps, it is because these conditions are
not satisfied.
operate after you do the above steps, it is because these conditions are
not satisfied.
•
When the AOF function is turned OFF, the machine is not in compliance with the
Energy Star requirements.