Makita RP2300FC 사용자 설명서

다운로드
페이지 27
[3] DISASSEMBLY/ASSEMBLY
[3]-1. Base complete (cont.)
DISASSEMBLING
4. Loosen Lock lever. 
    Base can be separated 
    from Motor section.
5. Remove Pole, Silent pole, Compression spring 13
    and Compression spring 11.
6. Remove Base plate by unscrewing
    M4x10 Countersunk head screw (4pcs.)
7. Remove Lock plate by unscrewing M5x10 Set bolt (2pcs.) 
    Separate Compression spring 4 (2pcs.) from Lock plate.  
M4x10 
Countersunk 
head screw
(4pcs.)
Base plate
The other parts can be removed from Base
complete as illustrated below.
Lock plate
Compression 
spring 4 (2pcs.)
M5x10 Set bolt (2pcs.)
Motor section
M6 Hex nut 
M10 Screw
Remove M6 Hex nut, Flat washer 6
and M10 Screw.
Stopper
Compression spring 5
Compression spring 7
Compression
spring 7
Steel ball 7.1
M4x19 Thumb screw
M5x14 Thumb screw
M5x14 
Thumb screw
O ring 3
M6 Flat head screw
O ring 8
Flat washer 6
Fig. 3
Fig. 4
Fig. 5
(2) Remove Base plate, Lock plate, Compression spring 4 and other component parts.
      Refer to Figs. 4 and 5.
Silent pole
Pole
Compression 
spring 11
Compression 
spring 13
R
epair
P 4/ 27