7 Using the serial communication
You can control the monitor from a personal computer etc. via the RS-485 or RS-232C terminal.
•  Consult your dealer for the details of the external control specification.
<Communication specifications>
Input 
terminal
Cable
Terminal 
specification
Communication specifications
RS-485
A straight LAN cable
☞ See below
Baud Rate: 4800 bps
Data Bits: 8 bits
Parity: No parity
Stop Bits: 1 bit
Flow Control: No control
Communication Code: ASCII Code
RS-232C
A straight cable with a D-sub 
9-pin connector (male for the 
monitor, female for the personal 
computer etc.)
<Specifications of the RS-485 terminal>
<Specifications of the RS-232C terminal>
This is a female terminal.
1Starting the communication:
  connection command (!00BCN1Cr)
3Selecting “SDI 1” input (!00BINACr)
5Terminating the communication:
  termination command (!00BCN0Cr)
6Monitor’s status (@00BOKCr)
4Monitor’s status (@00BOKCr)
2Monitor’s status (@00BOKCr)
PC, etc.
Example of communication procedures
Monitor
External Control 
(cont.)
This is a female terminal.
•  The 7th terminal and the 8th terminal are connected.
Pin No.
Signal
1
NC
2
RXD
3
TXD
4
NC
5
GND
6
NC
7
RTS
8
CTS
9
NC
Pin No.
IN terminal signal
OUT terminal signal
1
TXD +
TXD +
2
TXD –
TXD –
3
RXD +
RXD +
4
NC
NC
5
NC
NC
6
RXD –
RXD –
7
NC
NC
8
GND
GND
<Command outline>
All commands consist of the following segments.
Header
Monitor ID
Command ID
Function
Data
Cr (0Dh)
On Header
“!”: Operation commands from the personal computer, etc. (
 <Basic command list> on page 23).
“?”: Reference commands from the personal computer, etc.
“@”: Status returns from the monitor
To start communication, send the connection command from the personal computer etc.
To terminate the communication, send the termination command from the personal computer etc.