Triggered Recording 
3-100
 
MTM400 MPEG Transport Stream Monitor User Manual 
Triggered Recording Settings 
The Settings section of the Triggered Recordings dialog is used to set up the 
trigger event, including the pre-trigger properties and the amount of memory to be 
reserved for the recording. 
 
Trigger Type 
The event that triggers the recording can be one of four types, 
selected from the drop-down list. 
 
Immediate 
The trigger is set as soon as Arm Trigger is selected on the 
Operations section; in effect, recording will start immediately. 
 
External Rising Edge / External Falling Edge 
The trigger is set when Arm Trigger has been selected on the 
Operations section. Recording will start when a rising / falling 
edge is detected at the TTL input on the TS Processor, Alarms 
connector (see the MTM400 Technical Reference for 
specifications). 
 
Event Alarm
 
The trigger is set when Arm Trigger has been selected on the 
Operations section. Recording will start when an error occurs 
on an event that has been flagged in the Tests or Custom views.