Triggered Recording 
MTM400 MPEG Transport Stream Monitor User Manual 
3-103
 
The proportion of pre-trigger data may be less than specified if the trigger event 
occurred before enough packets were recorded in the circular buffer (particularly 
after clearing the buffer). 
For example, if the available memory will hold a 20 second recording, with 25% 
pre-trigger specified and an event-triggered recording starting five seconds or more 
into the run, the contents of the recorded file will be: 
Run
10
20
30
Trigger
time in seconds
0
25%
75%
File
 
If the Trigger event was detected earlier than five seconds into the run, the 
20 second file will contain all of the data up to the Trigger. If recording was 
triggered at three seconds only the first 15% of the file would hold pre-trigger data. 
The file contents would be: 
Run
10
20
30
Trigger
time in seconds
0
15%
85%
File
 
Triggered Recording Operation 
The Operation section of the Triggered Recordings dialog is used to arm the 
trigger before recording and shows the status of the recording activity.