Tektronix MTM400 사용자 설명서

다운로드
페이지 197
Interface Configuration and Interpretation 
3-118
 
MTM400 MPEG Transport Stream Monitor User Manual 
QAM (Annex B II)  
The QAM (Annex B II) Settings dialog box is shown in Figure 3-42.  
Configuration - QAM (Annex B II) 
 
Figure 3-42: Interface configuration – QAM Annex B II 
For each of the settings, enter the required change and select Set to apply the new 
value. The settings are as follows: 
NOTE. These settings can also be made from the Input Card screen. 
Configurations:  The QAM Settings dialog provides an option to recall a number 
of settings configuration files. The configuration files are created 
and stored in the MTM400. To select a configuration file, 
highlight the required name in the list. 
Tuner Frequency (kHz):  
This value, set in kHz units, is the center frequency of the 
channel to be received. Any frequency can be entered. There is 
no need to follow a channel plan. The frequency resolution is 
determined by the tuner step size of 62.5 kHz.