Stream View 
3-28
 
MTM400 MPEG Transport Stream Monitor User Manual 
Select the Close button to retain the temporary settings and close the dialog. 
Information Screen 
The Information screen displays stream events and messages.  
Stream events and messages may be logged but do not constitute a test failure; for 
example, a version change of a table carried in the SI/PSI is reported in the stream 
log but is not subject to a standard test. The only place that these stream events are 
recorded is in the stream logs. This screen collects these all in one place and allows 
their recording in the stream log to be enabled or disabled. Alarms can be raised 
when a message occurs.  
The messages to be displayed are set at the factory; interface cards can also 
generate messages.  
 
Figure 3-11: Stream view - Information 
The layout and functionality is similar to the Tests screen; a single column of icons 
is added, that is Log.  
Log
 
 Off 
; On - 
Enables/disables message recording in the stream log. 