Marshall electronic V-R653-IMD-TE 사용자 설명서

다운로드
페이지 28
 
Installation and Initial Setup
 
 
  Unpacking 
 
 
Carefully unpack the V-R653-IMD-TE monitor and verify that the following items are included: 
 
 
 
• V-R653-IMD-TE Monitor 
 
 
• V-PS12-6.6A Power Supply with 2-Pin Twist Lock Connector 
 
 
• Operating Instructions 
 
Inspect the unit for any physical damage that may have occurred during shipping. Should there be any damage, 
immediately contact Marshall Electronics at (800) 800-6608. If you are not located within the continental United States, 
call +1 (310) 333-0606. 
 
 
  Installation 
 
The V-R653-IMD-TE can be mounted in any standard EIA 19” equipment rack.  The attached rack ears can be angled 
to provide the user control over the viewing angle.  Adequate ventilation is required when installed to prevent possible 
damage to the monitor’s internal components. 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  Connections, Power-On and Initial Setup 
 
Plug the V-PS12-6.6A power supply into an AC power source (100-240 V @ 50/60 Hz). Attach the 2-pin twist lock 
connector to the back of the monitor. Please note that 12VDC can be also supplied directly to the monitor from a 
variety of sources. The monitor will draw no more than 6.0 Amps at 12 Volts in operation. 
 
Connect the required cables for video signal input and output. (Power must be applied to the V-R653IMD-TE for the 
active loop-though outputs to be activated.) All BNC connectors are rated at 75
Ω
 
All screens default to ‘ON’ when power is supplied. Video will automatically be detected and displayed on the screen. 
 
For IMD setup details, see IMD Configuration Submenu on page 22.
 
 
                      
 
Rack ears on either side of monitor