4.3.1
Identify Device command
The Identify Device command (command code EC
H
) transfers information about the drive to the host following
power up. The data is organized as a single 512-byte block of data, whose contents are shown in the table on
page 27. All reserved bits or words should be set to zero. Parameters listed with an “x” are drive-specific or
vary with the state of the drive. See Section 2.0 on page 3 for default parameter settings.
page 27. All reserved bits or words should be set to zero. Parameters listed with an “x” are drive-specific or
vary with the state of the drive. See Section 2.0 on page 3 for default parameter settings.
The following commands contain drive-specific features that may not be included in the Serial ATA specifica-
tion.
tion.
Standby Immediate
94h or E0h
ATA-standard security commands
Security Set Password
F1h
Security Unlock
F2h
Security Erase Prepare
F3h
Security Erase Unit
F4h
Security Freeze Lock
F5h
Security Disable Password
F6h
Word
Description
Value
0
Configuration information:
• Bit 15: 0 = ATA; 1 = ATAPI
• Bit 7: removable media
• Bit 6: removable controller
• Bit 0: reserved
0C5A
H
1
Number of logical cylinders
16,383
2
ATA-reserved
0000
H
3
Number of logical heads
16
4
Retired
0000
H
5
Retired
0000
H
6
Number of logical sectors per logical track: 63
003F
H
7–9
Retired
0000
H
10–19
Serial number: (20 ASCII characters, 0000
H
= none)
ASCII
20
Retired
0000
H
21
Retired
0400
H
22
Obsolete
0000
H
23–26
Firmware revision (8 ASCII character string, padded with
blanks to end of string)
blanks to end of string)
x.xx
Command name
Command code (in hex)