                                              5K320 SATA OEM Specification 
140 
  
02h 
SET MAX LOCK 
  
03h 
SET MAX UNLOCK 
  
04h 
SET MAX FREEZE LOCK 
  
When the Set Max ADDRESS command is executed, this register is 
ignored. 
B 
Option bit for selection whether nonvolatile or volatile. B=0 is volatile 
condition. When B=1, MAX LBA/CYL which is set by Set Max 
ADDRESS command is preserved by POR. When B=0, MAX LBA/CYL 
which is set by Set Max ADDRESS command will be lost by POR. 
LBA Low 
in LBA mode, this register contains LBA bits 0 - 7 which is to be 
input.(L=1) 
In CHS mode, this register is ignored. (L=0) 
LBA High/Mid 
In LBA mode, this register contains LBA bits 8 - 15 (Mid), 16 - 23 (High) 
which is to be set. (L=1) 
In CHS mode, this register contains max cylinder number which is to be 
set. (L=0) 
H 
In LBA mode, this register contains LBA bits 24 - 27 which is to be 
input.(L=1) 
In CHS mode, this register is ignored. (L=0) 
L 
LBA mode.Indicates the addressing mode.L=0 specifies CHS mode and 
L=1 does LBA addressing mode. 
Input Parameters From The Device 
LBA Low 
In LBA mode, this register contains Adjusted max LBA bits 0 - 7.(L=1) 
In CHS mode, this register contains max LBA Low(= 63). (L=0) 
LBA High/Mid 
In LBA mode, this register contains Adjusted max LBA bits 8 - 15 (Mid), 
16 - 23 (High). (L=1) 
In CHS mode, this register contains max cylinder number which is set. 
(L=0) 
H 
In LBA mode, this register contains Adjusted max LBA bits 24 - 27. (L=1)
In CHS mode, this register contains max head number(= 15).(L=0)