Hitachi HTS543280L9SA00 사용자 설명서

다운로드
페이지 177
 
                                              5K320 SATA OEM Specification 
146 
 
S.M.A.R.T. Read Attribute Thresholds (Subcommand 
D1h)  
This subcommand returns the device’s Attribute Thresholds to the host. Upon receipt of the 
S.M.A.R.T. Read Attribute Thresholds subcommand from the host, the device    reads the Attribute 
Thresholds from the Attribute Threshold sectors and then waits for the host to transfer the 512 
bytes of Attribute Thresholds information from the device.   
 
S.M.A.R.T. Enable/Disable Attribute Autosave 
(Subcommand D2h)   
This subcommand enables and disables the attribute autosave feature of the device. The S.M.A.R.T. 
Enable/Disable Attribute Autosave subcommand allows the device to automatically save its updated 
Attribute Values to the Attribute Data Sector at the timing of the first transition to Active idle mode 
after 30 minutes since the last saving of Attribute Values; this subcommand causes the autosave 
feature to be disabled. The state of the Attribute Autosave feature (either enabled or disabled) will 
be preserved by the device across power cycle.   
A value of 00h written by the host into the device’s Sector Count Register before issuing the 
S.M.A.R.T. Enable/Disable Attribute Autosave subcommand will cause this feature to be disabled. 
Disabling this feature does not preclude the device from saving Attribute Values to the Attribute 
Data sectors during some other normal operation such as during a power-up or power-down.   
A value of F1h written by the host into the device’s Sector Count Register before issuing the 
S.M.A.R.T. Enable/Disable Attribute Autosave subcommand will cause this feature to be enabled. 
Any other non-zero value written by the host into this register before issuing the S.M.A.R.T. 
Enable/Disable Attribute Autosave subcommand will not change the current Autosave status but the 
device will respond with the error code specified in “Table 124 S.M.A.R.T. Error Codes” on Page 159.   
The S.M.A.R.T. Disable Operations subcommand disables the autosave feature along with the 
device’s S.M.A.R.T. operations.   
Upon the receipt of the subcommand from the host the device enables or disables the Autosave 
feature.  
 
S.M.A.R.T. Save Attribute Values (Subcommand D3h)   
This  subcommand  causes  the  device  to  immediately save any updated Attribute Values to the 
device’s Attribute Data sector regardless of the state of the Attribute Autosave feature. Upon receipt 
of the S.M.A.R.T. Save Attribute Values subcommand from the host, the device writes any updated 
Attribute Values to the Attribute Data sector.   
 
S.M.A.R.T. Execute Off-line Immediate (Subcommand 
D4h)  
This subcommand causes the device to immediately initiate the set of activities that collect Attribute 
data in an off-line mode (off-line routine) or execute a self-test routine in either captive or off-line 
mode.  
The LBA Low register shall be set to specify the operation to be executed.   
LBA Low   
Operation to be executed 
0 
Execute S.M.A.R.T. off-line data collection routine immediately 
1 
Execute S.M.A.R.T. Short self-test routine immediately in off-line mode 
2 
Execute S.M.A.R.T. Extended self-test routine immediately in off-line mode 
Reserved 
Execute SMART Selective self-test routine immediately in off-line mode 
127 
Abort off-line mode self-test routine 
128 
Reserved 
129 
Execute S.M.A.R.T. Short self-test routine immediately in captive mode 
130 
Execute S.M.A.R.T. Extended self-test routine immediately in captive mode