Hitachi HDP725050GLA360 사용자 설명서

다운로드
페이지 258
Hitachi hard disk drive specifications   
108 
11.2  Configure Stream (51h) 
 
Command Block Output Registers
 
 
Command Block Input Registers
 
Register
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
 
Register
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
Data Low
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Data Low
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Data High
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Data High
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Feature
 
Current
 
V
 
V
 
-
 
-
 
-
 
V
 
V
 
V
 
 
Error
 
...See Below...
 
Previous
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
 
Sector Count
 
Current
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
Sector Count
 
HOB=0
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Previous
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
HOB=1
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Sector Number
 
Current
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Sector Number
 
HOB=0
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Previous
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
HOB=1
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Cylinder Low
 
Current
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Cylinder Low
 
HOB=0
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Previous
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
HOB=1
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Cylinder High
 
Current
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Cylinder High
 
HOB=0
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Previous
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
HOB=1
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Device/Head
 
1
 
1
 
1
 
D
 
-
 
-
 
-
 
-
 
 
Device/Head
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Command
 
0
 
1
 
0
 
1
 
0
 
0
 
0
 
1
 
 
Status
 
...See Below...
 
 
Error Register
 
 
Status Register
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
CRC
 
UNC
 
0
 
IDN
 
0
 
ABT
 
T0N
 
AMN
 
 
BSY
 
RDY
 
SE
 
DSC
 
DRQ
 
COR
 
IDX
 
ERR
 
0
 
0
 
0
 
0
 
0
 
V
 
0
 
0
 
 
0
 
V
 
0
 
V
 
-
 
0
 
-
 
V
 
Table 70    Configure Stream Command (51h) 
 
The Configure Stream command specifies the operating parameters of an individual stream. A Configure 
Stream command may be issued for each stream that is to be added or removed from the current operating 
configuration. If A/R = 1 and the specified ID is already valid at the device, the new parameters shall replace the 
old parameters, unless Command Abort is returned (see abort conditions for Error Register). In this case the old 
parameters for the specified Stream ID shall remain in effect. 
 
Abort conditions for Error register are the following. 
  The device does not support the Streaming Feature Set. 
  A/R is cleared to zero and the Feature field contains a Stream ID that has not been sent in a previous 
CONFIGURE STREAM command.