Fujitsu C120-H007-06EN 사용자 설명서

다운로드
페이지 136
94
C120-H007-05EN
CHAPTER 7 Protection Against Lightning
 
7.2
Protection of Signal Lines
(1) External modem is in use
When modems are installed, damage to internal circuitry components in the modems 
could result from indirect strike surges. Hence, it is recommended to install the 
appropriate surge absorber.
Some modems are equipped with surge absorber within them. If modems are 
installed, and the modem does not have surge absorber, installation of an external 
surge absorber should be considered. 
 lists recommended surge absorber.
Figure 7.3  Lighting control action when using external modem
 shows the recommended surge absorber.
(2) LAN connection
For the connection of outdoor LAN, optical cable should be applied as shown in 
Figure 7.4  Lightning control action for LAN cables
Table 7.2  Recommended surge absorber for external modem
Model
Manufacture
FPZ-100-2