Controls, LEDs, and Connectors
MVME2500 Installation and Use (6806800L01H)
58
Note that this switch is wired in parallel with the geographical address pins on the 5-row 
connector. These switches must be in the "OFF" position when installed in a 5-row chassis in 
order to get the correct address from the P1 connector. This switch also includes the SCON 
control switches.
Figure 3-5
Geographical Address Switch
Table 3-19 Geographical Address Switch  
Position
Function
Default
S1-1
VME SCON Auto
1
Auto-SCON
S1-2
VME SCON SEL
2
Non-SCON
S1-3
GAP
1
S1-4
GAP4
1
S1-5
GAP3
1
S1-6
GAP2
1
S1-7
GAP1
1
S1-8
GAP0
1
1. The VME SCON MAN switch is "OFF" to select Auto-SCON mode. The switch is "ON" to select 
manual SCON mode whichworks in conjunction with the VME SCON SEL switch.
2. The VME SCON SEL switch is OFF to select non-SCON mode. The switch is ON to select always 
SCON mode. This switch is only effective when the VME SCON MAN switch is "ON".