Omega 1002 사용자 설명서

다운로드
페이지 48
 
2.2  Jumper Setting 
 
There is only one jumper on the OME-PCI-1002. JP1 is used to select 
the analog input type. For single-ended inputs, users should connected pin 1, 3 
and pin 2, 4. For differential inputs, Pin 3, 5 and Pin 4, 6 should be connected. 
 
JP1 
JP1 
 
 
2
1
 
 
6
5
 
Differential 
Inputs
 
Single-ended 
Inputs (Default) 
 
 
 
 
 
 
 
2.3  A/D Calibration 
 
 
  
      
•  A/D Calibration for OME-PCI-1002 card 
      Step 1: Apply +10V to channel 0. 
      Step 2: Apply +0V to channel 1. 
      Step 3: Apply -10V to channel 2. 
      Step 4: Run DEMO6.EXE. 
      Step 5: Adjust VR1 until channel 0 = fff or ffe 
      Step 6: Adjust VR2 until channel 1 = 800 or 801 
      Step 7: Adjust VR3 until channel 2 = 000 or 001           
      Step 8: Repeat Step 4 & Step 5 & Step 6 until all read 
properly. 
VR1, VR2, VR3 
 
 
 
 
14