Drolet DB03122 사용자 설명서

다운로드
페이지 58
Escape 1400 Insert Installation and Operation Manual 
 
40 
8.3  Suitable Chimneys 
Your wood insert will provide optimum efficiency and performance when connected to a 6-
inch diameter chimney liner. The connection to a chimney having a diameter of at least 5 
inches (Canada only) is permitted, if it allows the proper venting of combustion gases and 
that  such  application  is  verified  and  authorized  by  a  qualified  installer.  Otherwise,  the 
diameter  of  the  flue  should  be  6  inches.  The  reduction  of  liner  diameter  to  less  than  6” 
should only be done if the total height of the masonry chimney is greater than 20 feet. 
8.4  Liner installation 
We  recommend  the  use  of  a  chimney  liner 
(rigid  or  flexible)  to  ensure  satisfactory 
performance.    To  ensure  an  optimal  draft,  we 
also strongly recommend adding a minimum of 
12”  rigid  liner  between  the  top  of  the  masonry 
chimney  and  the  rain  cap.    In  all  cases,  liners 
should be installed in accordance with the liner 
manufacturer’s 
instructions, 
including 
instructions for extension above the masonry. 
Use  Listed  Chimney  Liners  –  UL  1777, 
CAN/ULC S635 and CAN/ULC S640. 
In  order  to  connect  the  insert  to  the  liner,  refer 
to Section 9.5 Chimney liner installation.  
WARNING:    When  positioning  the  unit  in  a 
fireplace  opening  prior  to  the  flue  installation, 
install the insert into the opening until the top lip 
of air jacket is flush with fireplace facing. 
If lag-bolts or anchors are to be used to secure 
the insert, the hole locations should be marked 
with  the  unit  in  place.    Remove  the  insert  and 
locate the anchors.