8.8  Supply of Combustion Air 
In Canada, wood inserts are not required to have a supply of combustion air from outdoors 
because  research  has  shown  that  these  supplies  do  not  give  protection  against  house 
depressurization and may fail to supply combustion air during windy weather. However, to 
protect  against  the  risk  of  smoke  spillage  due  to  house  depressurization,  a  carbon 
monoxide (CO) detector/alarm is required
 in the room where the insert is installed. The 
CO detector will provide warning if for any reason the wood insert fails to function correctly. 
8.8.1  Air Supply in Conventional Houses 
The safest and most reliable supply of combustion air for your wood insert is from the room 
in  which  it  is  installed.  Room  air  is  already  preheated  so  it  will  not  chill  the  fire,  and  its 
availability  is  not  affected  by  wind  pressures  on  the  house.  Contrary  to  commonly 
expressed concerns, almost all tightly-sealed new houses have enough natural leakage to 
provide  the  small  amount  of  air  needed  by  the  insert.  The  only  case  in  which  the  wood 
insert  may  not  have  adequate  access  to  combustion  air  is  if  the  operation  of  a  powerful 
exhaust  device  (such  as  a  kitchen  range  exhaust)  causes  the  pressure  in  the  house  to 
become negative relative to outdoors.  
If you do install an air supply through the wall of the house, be aware that its pressure can 
be  affected  during  windy  weather.  If  you  notice  changes  in  wood  insert  performance  in 
windy weather, and in particular if smoke puffs from the insert, you should disconnect the 
outdoor air duct from the insert and remove the duct. In some windy conditions, negative 
pressure  at  the  duct  weatherhood  outside  the  house  wall  may  draw  hot  exhaust  gases 
from the insert backwards through the duct to outdoors. Check the outdoor air duct for soot 
deposits when the full system is cleaned and inspected at least once each year.