OME-A-826PG Software Manual [Win 95/98/NT] 
 
2.2.3 A826U.BAS 
 
Attribute VB_Name = "A826u" 
 
'*-----------------------------------------------------* 
'* Return voltage value or -100.0 if any error occurs  * 
'* or parameter is out of range.                       * 
'* Gain : 0-3 
'*-----------------------------------------------------* 
Function A826_AD2F(ByVal hex As Integer, ByVal Gain As Integer) As Single 
    Dim ZeroBase, BullRange, VoltageRange As Single 
     
    ZeroBase = 0# 
    FullRange = 32767# 
    VoltageRange = 10# 
    Gain = Gain Mod 16 
    If Gain < 0 Or Gain > 3 Then 
        A826_AD2F = -100# 
        Exit Function 
    End If 
     
    A826_AD2F = ((((hex - ZeroBase) / FullRange) * VoltageRange) / (2 ^ Gain)) 
End Function 
 
 
2.2.4 
The VB Demo Result: 
 
 
Date: Aug-15-2000             Ver: 2.2                                                                                         Page  21