2.4.1  The 8254 Counter  
 
The 8254 Programmable timer/counter has 4 registers from Base+0 through 
Base+3. For detailed programming information about the 8254, please refer 
to Intel‘s “Microsystem Components Handbook”. 
 
Address Read 
Write 
Base+0 
8254 Counter 0 
8254 Counter 0 
Base+1 
8254 Counter 1 
8254 Counter 1 
Base+2 
8254 Counter 2 
8254 Counter 2 
Base+3 
Reserved 
8254 Counter Control 
 
 
 
 
2.4.2    A/D Input Buffer Register 
 
(READ)    Base+4: A/D Low Byte Data Format 
Bit 7 
Bit 6 
Bit 5 
Bit 4 
Bit 3 
Bit 2 
Bit 1 
Bit 0 
D7 D6 D5 D4 D3 D2 D1 D0 
 
(READ)    Base+5: A/D High Byte Data Format 
Bit 7 
Bit 6 
Bit 5 
Bit 4 
Bit 3 
Bit 2 
Bit 1 
Bit 0 
0 0 0 READY 
D11 
D10 
D9 
D8 
 
A/D 12 bit data: D11…..D0, D11 = MSB, D0 = LSB 
READY   = 1: A/D 12 bits data not ready 
 
 
 
= 0: A/D 12 bits data is ready 
 
The low 8 bits of A/D data are stored in address BASE+4 and the high 4 bits of data are 
stored in address BASE+5. The READY bit is used as an indicator for A/D conversion. 
When a A/D conversion is completed, the READY bit will be cleared to zero (Low). 
OME-A-8111 Hardware Manual (ver.1.1, Jul/2003)                                      12