8.5.1.1
Adding a Custom Dataset
WinVCC in Depth
Figure 15. System Initialization
After programming the EVM via the System Initialization tool using the factory-supplied command file, you
can customize the device register settings to fit your needs. Perform the following steps to save your
custom settings:
1. Reopen the System Initialization dialog box via the Tools menu.
2. Click the Append Current Device Settings to Command File button. A dialog box requesting a
description of the new dataset appears.
3. Optionally, click the drop-down box and select one of the existing descriptions.
4. Modify the description text or type your own description.
5. Click OK. All nondefault register values from the TVP5154, DM642, and encoder are appended to the
current command file as an additional dataset.
Now, you can select your custom dataset and send it with a press of the Program
button.
By using the same procedure above with the Replace Selected Dataset with Current Device Settings
button you can overwrite an existing dataset with the current settings.
Note:
If editing the command file (.CMD) using a standard editor, the file must be saved as plain
text.