IBM 8314 사용자 설명서

다운로드
페이지 314
Chapter
 
2.
 
General
 
Checkout
 
This
 
general
 
checkout
 
procedure
 
is
 
for
 
Types
 
8301,
 
8302,
 
8303,
 
8304,
 
8305,
 
8306,
 
8307,
 
8308,
 
8309,
 
8310,
 
8311,
 
8312,
 
8313,
 
8314,
 
and
 
8315
 
computers.
  
Attention:
   
The
 
drives
 
in
 
the
 
computer
 
you
 
are
 
servicing
 
might
 
have
 
been
 
rearranged
 
or
 
the
 
drive
 
startup
 
sequence
 
changed.
 
Be
 
extremely
 
careful
 
during
 
write
 
operations
 
such
 
as
 
copying,
 
saving
 
or
 
formatting.
 
Data
 
or
 
programs
 
can
 
be
 
overwritten
 
if
 
you
 
select
 
an
 
incorrect
 
drive.
  
Diagnostic
 
error
 
messages
 
appear
 
when
 
a
 
test
 
program
 
finds
 
a
 
problem
 
with
 
a
 
hardware
 
option.
 
For
 
the
 
test
 
programs
 
to
 
properly
 
determine
 
if
 
a
 
test
 
Passed,
 
Failed
 
or
 
Aborted,
 
the
 
test
 
programs
 
check
 
the
 
error-return
 
code
 
at
 
test
 
completion.
 
See
 
 
 
 
 
General
 
error
 
messages
 
appear
 
if
 
a
 
problem
 
or
 
conflict
 
is
 
found
 
by
 
an
 
application
 
program,
 
the
 
operating
 
system,
 
or
 
both.
 
For
 
an
 
explanation
 
of
 
these
 
messages,
 
refer
 
to
 
the
 
information
 
supplied
 
with
 
that
 
software
 
package.
  
Notes:
 
v
   
Types
 
8301,
 
8302,
 
8303,
 
8304,
 
8305,
 
8306,
 
8307,
 
8308,
 
8309,
 
8310,
 
8311,
 
8312,
 
8313,
 
8314,
 
and
 
8315
 
computers
 
default
 
to
 
come
 
up
 
quiet
 
(no
 
beep
 
and
 
no
 
memory
 
count
 
and
 
checkpoint
 
code
 
display)
 
when
 
no
 
errors
 
are
 
detected
 
by
 
POST.
 
v
   
To
 
enable
 
beep
 
and
 
memory
 
count
 
and
 
checkpoint
 
code
 
display
 
when
 
a
 
successful
 
POST
 
occurs,
 
do
 
the
 
following:
 
1.
   
Select
 
Start
 
Options
 
in
 
the
 
Configuration/Setup
 
Utility
 
program
 
(see
 
 
 
 
 
 
 
2.
    
Set
 
Power-On
 
Self-Test
 
to
 
Enhanced
.
v
   
Before
 
replacing
 
any
 
FRUs,
 
ensure
 
that
 
the
 
latest
 
level
 
of
 
BIOS
 
is
 
installed
 
on
 
the
 
system.
 
A
 
down-level
 
BIOS
 
might
 
cause
 
false
 
errors
 
and
 
unnecessary
 
replacement
 
of
 
the
 
system
 
board.
 
For
 
more
 
information
 
on
 
how
 
to
 
determine
 
and
 
obtain
 
the
 
latest
 
level
 
BIOS,
 
see
 
 
 
 
 
 
v
   
If
 
multiple
 
error
 
codes
 
are
 
displayed,
 
diagnose
 
the
 
first
 
error
 
code
 
displayed.
 
v
   
If
 
the
 
computer
 
hangs
 
with
 
a
 
POST
 
error,
 
go
 
to
 
″Symptom-to-FRU
 
Index
 
on
 
page
 
 
v
   
If
 
the
 
computer
 
hangs
 
and
 
no
 
error
 
is
 
displayed,
 
go
 
to
 
 
 
 
 
 
v
   
If
 
an
 
installed
 
device
 
is
 
not
 
recognized
 
by
 
the
 
diagnostics
 
program,
 
that
 
device
 
might
 
be
 
defective.
  
001
 
1.
   
Power-off
 
the
 
computer
 
and
 
all
 
external
 
devices.
 
2.
   
Check
 
all
 
cables
 
and
 
power
 
cords.
 
3.
   
Make
 
sure
 
the
 
system
 
board
 
is
 
seated
 
properly.
 
4.
   
Set
 
all
 
display
 
controls
 
to
 
the
 
middle
 
position.
 
5.
   
Power-on
 
all
 
external
 
devices.
 
6.
   
Power-on
 
the
 
computer.
 
7.
    
Check
 
for
 
the
 
following
 
response:
 
v
   
Readable
 
instructions
 
or
 
the
 
Main
 
Menu.
 
©
 
Copyright
 
IBM
 
Corp.
 
2001
 
3