4: Configuration Using XML
PremierWave EN Command Reference
18
Importing and Exporting an XML Configuration File
An XCR can be imported or exported using the following methods:
Filesystem-XCRs can be saved to the device server file system and imported or accessed as 
needed. See 
 or the Filesystem Browser section in the 
PremierWave EN User Guide.
CLI-XCRs can be imported (captured) or exported (dumped) directly to a Telnet, SSH, or 
serial line CLI session. Capturing an XCR can be started by pasting a valid XCR directly into 
the CLI prompt. PremierWave EN immediately processes the configuration record, changing 
any settings specified. This can be done on any level, including the root. Special tags in the 
XML allow for providing root and enable level passwords so that this can also be done at the 
password prompt.
Web browser-Web Manager can be used to import and export an XCR to the device server file 
system.  It can also be used to import an XCR from an external source such as your local hard 
drive.
FTP-The device server FTP server can export and import XCRs when an FTP get or put 
command on the filename (pwen.xcr for export, pwen_import.xcr for import; both are under the 
pwxcr directory) is requested. On export (FTP get of pwen.xcr), the FTP server obtains the 
current XCR from the PremierWave EN and sends it as a file. On import (FTP put of 
pwen_import.xcr), the FTP server processes the file by sending it directly to the XML engine. 
In both cases the device server filesystem is not accessed. The files pwen.xcr and 
pwen_import.xcr are not read from or written to the file system. See FTP in the PremierWave 
EN User Guide
Best Practices
You can import or export an entire XCR, or just a portion of it, by specifying the group name and/or 
group instances. In the examples below, import and export operations are performed from the CLI 
on the local filesystem and require a XCR on the local filesystem. The Web Manager provides the 
same functionality.
Caution:
Using Microsoft Word to edit and save an XCR will change the format of 
the file and make it incompatible with PremierWave EN. This is true even 
if the file is saved as Plain Text (.txt) or an XML Document (.xml). 
Notepad, a third party text editor, or a specialized XML editor should be 
used instead.
Importing
The following syntax can be used to import configurations from a file:
xcr import <file> 
xcr import <file> <groups and/or group:instances> 
The first line imports all groups specified in the XML config record named in <file>. Any filename is 
valid, and the file name and extension are not important. 
In the second line:
Instance follows group with a colon (see the third example on the next page).
Multiple groups are separated with a comma.