 Installing options
 103
4.
From the Windows NT Server desktop, select Control Panel, then select the 
Network
 icon, then select the Adapters tab.
5.
Highlight one of the adapters that will be in the redundant pair and then click the 
Properties...
 button.
6.
Check the Grouping box.  This will show the possible combinations for redundant 
pairs.
7.
Select the adapter pair you want and then select OK.  Note that the integrated 
Ethernet controller is located at PCI C.  
Two options are available for recovering from a failover condition.  The options 
are determined by the Enable for DMI / Hot Swap Support checkbox.  If the IBM 
Hot Plug PCI for Windows NT Server 4.0 package is installed, this checkbox will 
appear at the bottom of the Adapter Properties panel.  If you do not have the IBM 
Hot Plug PCI for Windows NT Server 4.0 package installed on the server, you will 
not see the Enable for DMI / Hot Swap Support checkbox.
If the Enable for DMI / Hot Swap Support checkbox is not checked or is not 
present, traffic will automatically switch back to the primary adapter when the 
primary link status is restored.  In this mode, the adapter cannot be hot-swapped.  
Users with the IBM Hot Plug PCI for Windows NT Server 4.0 package installed 
should check the Enable for DMI / Hot Swap Support checkbox.
If the Enable for DMI / Hot Swap Support checkbox is checked, traffic will 
remain on the secondary adapter until the user directs it to return to the primary 
adapter.  This can be done after the hot-swap replacement of the primary adapter 
or by using the DMI interface.
8.
Select Close to exit from the Network setup.  
When you restart the server, the failover function will be in effect.
If a failover occurs, a message is written to the NT Event Viewer log.  In addition, if 
the Enable for DMI / Hot Swap Support checkbox is checked, a DMI alert will also be 
generated.
IntraNetWare:  The IBM PCI Hot Plug System Bus Driver Diskette for Novell Netware 
V4.41, V4.42, and V5.0 is available for download from the IBM Web site at:
http://www.pc.ibm.com/support
The failover function is now enabled.  If a failover occurs:  
The operating system console generates a message.  
The custom counters for the device driver contain variables that define the state of 
the failover function and the location of the redundant pair.  You can use the 
NetWare Monitor to view the custom counters.
Note:
If the primary adapter was hot-replaced while the Ethernet traffic was being 
handled by the secondary Ethernet controller, the traffic does not 
automatically switch back to the primary adapter when the primary adapter 
comes back online.  In this case, issue the command:  
LOAD d:\path\PCNTNW SCAN
  where d and path are the drive and path where the driver is located.  This 
command causes the device driver to locate the primary adapter and switch 
the Ethernet traffic to it.
Ethernet port connector
The following table shows the pin-number assignments for the RJ-45 connector.  
These assignments apply to both 10BASE-T and 100BASE-TX devices.