IBM 7RY 사용자 설명서

다운로드
페이지 226
© Copyright IBM Corp.  1999
 107
FRU information (service only)
Field Replacement Units (FRUs) should be replaced by qualified service personnel 
only.
Diagnostic switch card
Use the following illustration when replacing the diagnostic switch card.
Review the information in “Before you begin” on page 58.
∼1∼ Holding 
screw
∼2∼ Diagnostic 
switch 
card
1.
Power-off the server, if it is on.
2.
Disconnect the power cord for each power source from the electrical outlet.
Attention: 
  The presence of ac standby power might result in damage to the 
hardware unless you disconnect the power cord for each power source from the 
electrical outlet.
3.
4.
DIsconnect the shuttle (see “Disconnecting the shuttle” on page 108) and move it 
back slightly.
5.
Disconnect the front LED card assembly cable from the diagnostic switch card.
6.
Disconnect the diagnostic switch card cable.
7.
Remove the screw from the diagnostic switch card.
SM
I
NM
I
PC
IA
PCIB
PS
3
PS
4
SP
OVER
SPEC
ME
M
NON
RE
D
F A
N
TE
MP
VR
M
CPU
DAS
D1
PS2
PS
1
PCI
C