IBM 7RY 사용자 설명서

다운로드
페이지 226
 
 FRU information (service only)
 113
∼1∼ Retaining 
screws
∼2∼ 
Power backplane assembly
1.
Power-off the server, if it is on.
2.
Disconnect the power cord for each power source from the electrical outlet.
Attention: 
  The presence of ac standby power might result in damage to the 
hardware unless you disconnect the power cord for each power source from the 
electrical outlet.
3.
4.
5.
Remove the hot-swap power supplies (reverse the steps in “Installing a hot-swap 
power supply” on page 88).
6.
Turn the two retaining screws one-quarter turn.
7.
Lift the power backplane assembly.
8.
To replace the power backplane assembly, reverse this procedure.
Note:
When replacing the power backplane assembly, you must align the bottom 
of the assembly with the notches on the floor of the server. 
Processor/PCI backplane
Review the information in “Before you begin” on page 58.
Note:
Existing system configuration will be lost.  If possible, save the existing system 
configuration or obtain a previously saved copy.